Search
Search this site
33 results found with an empty search
- Forage NIR Analyzer for Hay & Silage | Phoenix 5000 | Blue Sun
30 second analysis of forages including alfalfa, hay, haylage, corn silage and more. Optional autosampler for high throughput laboratories. Phoenix 5000 NIR Forage Analyzer The Phoenix 5000 NIR forage analyzer delivers lab-grade results on alfalfa, corn silage, hay, haylage, and more in about 30 seconds per sample. A single scan returns dry matter, protein, ADF, NDF, fiber digestibility, and more — with no reagents and no destruction of the sample. Designed, built, and supported from our headquarters in Maryland, USA. Download Brochure Request More Info Two Configurations, One Platform The Phoenix 5000 forage analyzer comes in two configurations built around how your lab works. Both deliver 30-second analysis with the same accuracy — the difference is throughput and sample handling. For high-throughput labs Phoenix Sideloader Designed for labs running thousands of samples a year. Load the autosampler, walk away, and let it run unattended. Optional 30 or 50-cup autosampler Unattended, continuous operation Uses ISI ring cups (ground, homogeneous samples) Request a Consultation For sample flexibility Phoenix Top Window Designed for nutritionists, universities, and labs that analyze a range of sample types. Multiple cup types in one instrument Scans 99% of the sample area for lower sampling error Integrated check standard with drift prevention Request a Consultation Sideloader and Top Window Features Feature Sideloader Top Window Autosampler Yes (30 or 50 cup) No Sample Cups Ring cups only Large, ring, transflectance Sample Types Ground, homogeneous Ground, wet, unground Operation Unattended batches Attended, one at a time Best Fit Highest throughput Maximum flexibility Flexible Calibration Options An NIR analyzer is only as good as its calibration. The Phoenix gives you three ways to get there — including keeping the calibrations you've already built on another platform. Use a calibration partner Start with the same forage calibrations North America's leading forage labs rely on. A reliable forage calibration takes thousands of samples with matching wet chemistry results, collected across crops, regions and growing seasons. Few labs have that data when they bring in a new instrument, so most license calibrations from a provider that does. Five of North America's major forage calibration providers license their calibrations for use on the Phoenix, and each of them runs Phoenix analyzers in its own affiliate labs. When you license a calibration from one of these partners, you're using the same models on the same instrument platform their own labs use every day. Calibration partners Cumberland Valley Analytical Services (CVAS) Dairy One Dairyland Laboratories NIRS Consortium (NIRSC) Rock River Laboratory Bring your legacy database Already invested years building calibrations on another NIR platform? Keep them. The Phoenix is custom-built for transferability — its configurable wavelength intervals can be matched to your existing instrument, and our transfer algorithms align spectra while compensating for instrument, math-treatment, and wavelength-scale differences. In many cases, no new samples required. Build your own Develop and fully own your calibrations with the Alligator Calibrator chemometrics software. Traditional, trusted chemometric workflows, multi-constituent calibration, and complete control of your data — with no subscription, no hidden costs, and no internet connection required. See the Phoenix in Action Play Video Facebook Twitter Pinterest Tumblr Copy Link Link Copied Phoenix Sideloader with Autosampler Play Video Facebook Twitter Pinterest Tumblr Copy Link Link Copied Phoenix Top Window Phoenix 5000: Designed for Ease of Use Easy Operation Fill the cup, set it on the instrument, and scan — results in about 30 seconds. Flexible Data Handling Export results to Excel, LIMS, or Modbus, and review history anytime in BlueScan. Expert Support Our technology managers average 10+ years of hands-on NIR experience. High Performance NIR A scanning monochromator— a trusted NIR technology for reliable, precise, consistent results. Intuitive Software A simple four-tab, color-coded interface that operators learn and use with ease. Made in USA Every Phoenix 5000 is built and shipped from our headquarters in Maryland, USA. Trusted by Leading Forage Labs Since employing the Phoenix, it has far outshined what initially drew us to it. It's become the central workhorse of our laboratory network — South America, Europe, and the U.S. Don Meyer President, Rock River Laboratory It now takes one technician to run an instrument where it used to take two. Each instrument we add eliminates one FTE — a huge win for us. Phillip Goldblatt NIR Programs Manager, Dairyland Laboratories Our staff and students enjoy the software for its ease of use. The Blue Sun team strives to make the experience easier than anyone else in the business. David McIntosh Coordinator III, UT Beef & Forage Center CUSTOMER STORY Real-time feeding decisions at Wolf Creek Dairy "On-farm analysis allows us to know exactly what we are feeding the cows." — Rochelle Schroeder, DVM, Wolf Creek Dairy When forage results came back from an outside lab three to four days later, Wolf Creek Dairy was fine-tuning rations on data that was already stale. By bringing a Phoenix 5000 in-house, their team now analyzes forages in real time — right before they go into the total mixed ration — keeping the herd's diet consistent as they work through each pile. Read more: Enhancing Dairy Operations with On-Site NIR Analysis at Wolf Creek Dairy Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- NIR for Animal Nutrition | Phoenix Analyzers | Blue Sun
Near-infrared (NIR) analysis for the animal nutrition industry: protein, moisture, fat, fiber, and ash across forage, feed, rendering, and pet food. NIR Designed for Animal Nutrition Forage, feed, rendering, and pet food — the Phoenix NIR analyzer delivers the accuracy and speed that change how you test. Request Information Explore the Analyzers FORAGE FEED RENDERING PET FOOD Automate forage analysis across every crop A full forage analysis means 30+ parameters, each with its own chemistry method — some running hours or days. The NIRSC estimated a complete analysis at 325 operator-hours; NIR delivers the same analysis in minutes. The Phoenix Sideloader with Autosampler goes further — load up to 50 samples and it runs them automatically and unattended. That throughput is why many of North America's commercial agriculture labs — running hundreds of samples a day — adopted the Phoenix. Several are calibration providers themselves and offer their forage calibrations on the Phoenix, so a new lab can start on proven calibrations from day one. Explore the NIR Forage Analyzer → Measured head-to-head — and it led the field on accuracy A prospective buyer designed and ran the test: the Phoenix against three competing NIR and FT-NIR analyzers on soybean-meal protein. All four ran the same 21 samples, each on its own native commercial calibration, against an independent validation set held out from calibration. The customer designed and ran the evaluation — not the vendor Same 21 soybean-meal samples, protein 44.4–47.6% Each analyzer on its own native commercial calibration The Result The Phoenix had the lowest prediction error of the four analyzers: an SEP of 0.28% protein (R² 0.86), compared with 0.57, 0.65 and 0.90% (R² 0.52, 0.27 and 0.15) for the three competing NIR and FT-NIR analyzers. Explore the NIR Feed Analyzer → Agrees with the combustion lab — in seconds, not minutes A global protein processor evaluated the Phoenix using an independent validation set of 13 meat & bone meal samples. Protein predictions matched the LECO combustion reference with an SEP of 0.45% and R² of 0.98 across a 42–53% range (slope 1.00, bias +0.11, n = 13). Moisture (SEP 0.24, R² 0.95), fat (SEP 0.20, R² 0.80) and ash (SEP 0.69, R² 0.97) also tracked the reference closely. With no reagents and minimal sample preparation, NIR carries less operator variation — which translates into tighter repeatability, with results in seconds rather than minutes. As a secondary method, NIR cannot exceed the reference method's accuracy and typically carries 1–1.5× its error. The 0.45% SEP observed here is exactly consistent with that expectation. NIR's Honest Limitation Explore the NIR Rendering Analyzer → Every parameter becomes a quality-control point Pet-food quality is a process-control challenge: every bag must match, batch after batch. Moisture governs dryer control and shelf life; degree of cook reflects extruder conditions and drives digestibility and texture; protein and fat set palatability; ash tracks mineral consistency. Because results return in seconds, operators can adjust the dryer or extruder to bring a drifting batch back into spec — before it becomes rework. Explore the NIR Pet Food Analyzer THIS IS NIR DESIGNED FOR ANIMAL NUTRITION See how the Phoenix fits your lab or plant Tell us your samples and throughput, and we'll match you to the right configuration and calibrations — with a hands-on evaluation on your own material. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- Animal Feed NIR Analyzer | Phoenix 5000 | Blue Sun
Analyze protein, moisture, fat, fiber, starch and ash in animal feed in ~30 seconds with the Phoenix 5000 NIR analyzer. Made in USA. Request a quote. Phoenix 5000 NIR Feed Analyzer Get lab-quality feed analysis in seconds. The Phoenix 5000 animal feed NIR analyzer reads moisture, protein, fat, fiber, starch, and ash from a single scan — reagent-free and non-destructive — so feed producers can verify quality, formulate at lower cost, and meet label specs without the wait. Designed, built, and supported in the USA. Download Brochure Request Information Get to Know the Phoenix 5000 Feed Analyzer In this 3-minute video, see how the Phoenix 5000 NIR feed analyzer helps feed mills cut over-formulation: lab-quality moisture, protein, fat, fiber, starch and ash results in about 30 seconds, on everything from raw grains to finished pellets. What the Phoenix NIR 5000 Measures Moisture controls quality of incoming materials and prevents over/under-drying Protein hits formulation targets and label claims Fat monitors energy content and tracks fat in extruders and dryers Fiber assesses quality and digestibility Starch supports diet formulation and energy calculations Ash Indicates mineral content and contamination Feed Types Poultry Feed Check protein, moisture, and fat in poultry rations to keep formulations on target and minimize costs. Swine Feed Confirm nutrient levels across swine diets, from incoming materials to finished feed, keeping rations on spec. Cattle & Dairy Feed Analyze moisture, protein, and fiber in cattle and dairy rations to support consistent diets and efficient performance. Aquafeed Measure protein, fat, and moisture in aquafeed to hold tight nutritional specs for efficient, consistent nutrition. How Feed Mills Use NIR Analysis The Phoenix 5000 NIR analyzer simplifies the analysis of feed and feed ingredients by allowing multiple ingredients and finished products to be analyzed on the same instrument. NIR analysis offers rapid analysis of multiple parameters simultaneously, providing feed producers important insight and data for formulating diets for livestock, as well as in quality control and product development. The Phoenix 5000 can help feed millers optimize production in multiple ways including: Ingredients Monitor quality of incoming ingredients Confirm product quality for formulation Production Control Meet protein target Tighten upper and lower control limits Least Cost Formulation Bin bottom analysis Rapid decision making Finished Product Label deck Reduce laboratory costs NIR vs. Wet Chemistry: Why Feed Mills Choose NIR Wet chemistry is the accuracy benchmark — but it's slow, reagent-heavy, and costly per sample. NIR delivers results correlated to those same reference methods in seconds, so you can test far more often without the wait, the chemicals, or the lab bill. NIR Wet Chemistry Speed ~ 30 seconds Hours to days Reagents None Chemical reagents required Sample Non-destructive Sample consumed Parameters per run Several at once One assay at a time Cost per test Very low Higher (reagents + labor) Where you run it On-site, in-process Usually in a lab Wet chemistry remains the reference standard that NIR calibrations are built on — so NIR is your fast, everyday tool, with wet chemistry as the benchmark behind it. Read more: [NIR vs. Wet Chemistry for Feed Analysis] CUSTOMER STORY "On-farm analysis allows us to know exactly what we are feeding the cows." — Rochelle Schroeder, DVM, Wolf Creek Dairy Real-time feeding decisions at Wolf Creek Dairy When forage results came back from an outside lab three to four days later, Wolf Creek Dairy was fine-tuning rations on data that was already stale. By bringing a Phoenix 5000 in-house, their team now analyzes forages in real time — right before they go into the total mixed ration — keeping the herd's diet consistent as they work through each pile. Read more: [Enhancing Dairy Operations with On-Site NIR Analysis at Wolf Creek Dairy] Phoenix 5000: Designed for Ease of Use Easy Operation Fill the cup, set it on the instrument, and scan — results in about 30 seconds. Flexible Data Handling Export results to Excel, LIMS, or Modbus, and review history anytime in BlueScan. Expert Support Our technology managers average 10+ years of hands-on NIR experience. High Performance NIR A scanning monochromator— a trusted NIR technology for reliable, precise, consistent results. Intuitive Software A simple four-tab, color-coded interface that operators learn and use with ease. Made in USA Every Phoenix 5000 is built and shipped from our headquarters in Maryland, USA. Phoenix 5000 Specifications TECHNOLOGY & PERFORMANCE NIR Technology Scanning Monochromator Detector High-performance InGaAs Wavelength Range 1100-2500 nm Spectral Resolution 0.5, 1.0, 2.0 nm (selectable) Measurement Mode Reflectance or transflectance Analysis Time 10 - 60 seconds (~30 seconds typical) Wavelength Accuracy <0.05 nm matched to an internal reference standard Drift Control Internal Drift Prevention with embedded standards SAMPLE HANDLING Sample Cups Large, small, custom Sample Prep Little to none DATA & SOFTWARE Software BlueScan Data Export Excel, LIMS, Modbus Operating System Windows 10/11 Need the complete datasheet? The brochure has full dimensions, power and environmental specs, as well as the Phoenix 5000 vs. 6000 comparison.[Download the Phoenix brochure (PDF)] Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- NIR Analyzer for Universities & Research | Phoenix 6000 | Blue Sun
Phoenix 6000 extended-wavelength NIR (600–2500nm) for university and research labs. The NIR Research & University package bundles instrument, training, and support at academic pricing. Phoenix 6000 NIR Research Analyzer The Phoenix 6000 gives research labs an extended 600–2500nm wavelength range and sample presentation that reads the whole sample, not a window of it — one platform flexible enough to follow the work wherever it goes. Through the University NIR Package, it arrives complete: instrument, sample accessories, installation, training, a year of calibration development, and ongoing support, at academic pricing. Designed, built, and supported in Maryland, USA. Download Brochure Request More Info The University NIR Package Universities are where most lifelong NIR users first meet the technology. Over 25 years, our research partners have developed the applications that expanded what NIR can do across entire industries — and this package exists to make that work easier to start. Academic labs fund instrumentation on grant cycles, so we built it as one line item: everything required to run an NIR program, at a discounted academic rate. Phoenix 6000 Instrument Extended 600–2500nm range, wide enough to cover a diverse array of research applications on one platform. Calibration Development One full year of calibration development included, so your models are productive while the program gets established. Academic Pricing The entire package is offered to universities and research institutes at a discounted academic rate. Sample Accessories A collection of sample accessories so the instrument adapts to whatever sample types your research requires. Phone & Remote Support Free phone and remote support — expert assistance is always a call or a click away, at no cost. Installation & Training Professional installation and comprehensive team training, so your lab is producing usable data from week one. One-Year Parts Warranty Every part covered for a full year, so an unexpected issue doesn't derail your research budget. Writing a proposal? We'll send you a quote for it. Equipment budgets are justified long before they're funded. Tell us what your lab is working on and we'll put together a written quote for the package you'd actually need — sized to your application, ready to drop into your budget justification. No obligation, and no need to have funding in hand. Request a Quote What the Phoenix NIR 6000 Measures Moisture The most widely modeled NIR constituent, and typically the first calibration a new program builds Protein Strong NIR response; central to feed, forage, grain, and oilseed work Fat & Oil Supports oilseed, rendering, and energy-density studies Fiber Structural carbohydrate analysis for forage and plant science Starch Digestibility and energy calculations Sugar Soluble carbohydrate work across crops and processed products Ash Mineral content and contamination These are the constituents most programs begin with. Your lab isn't limited to them — the full 600–2500nm range and a year of included calibration development are there to take you toward the constituents your own research targets. Built for Research, Not Just Routine Analysis A routine analyzer is built to run one commodity, the same way, for years. Research doesn't work like that. The samples change, the questions change, and the students change — and the instrument has to keep up with all of it. Extended 600–2500nm range A wider range than routine analyzers, spanning the visible and full near-infrared regions so one platform accommodates a diverse array of research applications rather than a single commodity. Total Sample Scan Innovative sample presentation analyzes the entire sample, not a small window of it — reducing the subsampling variation that undermines reproducibility. Your data stays yours Export results to Excel or LIMS and review the full history in BlueScan — the instrument feeds your analysis rather than trapping results inside itself. Calibration Flexibility Use a calibration from one of our partners, or transfer a database you developed on a legacy NIR platform. Your first year of calibration development is included either way. Published Research Using Phoenix NIR Instruments Phoenix instruments appear in the peer-reviewed literature across grassland science, agronomy, and animal nutrition — including a sustained body of work from the grassland research group at the University of Göttingen. USDA‑ARS · Auburn · Iowa State · Kansas State University of Göttingen · Scibus / Fermentrics Viticulture · agronomy · poultry & animal nutrition · grassland science · 2021–2026 Weerarathne et al., 2025 Rapid Determination of Bud and Leaf Water Content Using Hyperspectral Sensors to Monitor Cold Hardiness in Grapevine American Journal of Enology and Viticulture · 10.5344/ajev.2025.25019 USDA-ARS researchers used NIR bud absorbance as a proxy for grapevine cold hardiness, screening 86 breeding progenies against the traditional thermal-analysis method. Moran et al. 2025 Improving Groundcover Establishment Through Seed Rate, Seed Ratio, and Hydrophilic Seed Coating Agronomy 15(8):1927 DOI: 10.3390/agronomy15081927 Iowa State evaluated seeding rate, seed ratio, and hydrophilic coating for establishing Kentucky bluegrass as a perennial groundcover in corn production. Baral et al. 2025 Cropping potential of forage soybean as a summer forage in Midwest U.S. rainfed systems Frontiers in Agronomy DOI: 10.3389/fagro.2025.1570567 Kansas State assessed forage soybean as a summer forage option for Midwest rainfed cropping systems. Vargas et al., 2023 — Auburn University Effect of Corn Origin on Broiler Performance, Processing Yield, and Nutrient Digestibility from 1 to 35 Days of Age Animals 13:1248 · DOI: 10.3390/ani13071248 How corn source affects broiler growth, processing yield, and nutrient digestibility. Marques et al., 2025 — Brazil (UFG) Use of Bacterial-Enzymatic Inoculant Improves Silage Quality and Reduces Fermentation Losses in Intercropped Systems Agriculture 15(4):437 · DOI: 10.3390/agriculture15040437 A bacterial-enzymatic inoculant for improving silage quality in intercropped forage systems. Lean et al., 2026 — Scibus (Australia) / Fermentrics (Canada) Microbial inoculation of a grass-dominant pasture improves rumen function in vitro Frontiers in Animal Science 7 · DOI: 10.3389/fanim.2026.1817050 How a microbial pasture inoculant changes rumen fermentation in vitro — a commercial-lab deployment. Two Configurations, One Platform The Phoenix 6000 research analyzer comes in two configurations built around how your lab works. Both deliver 30-second analysis with the same accuracy — the difference is throughput and sample handling. For high-throughput labs Play Video Facebook Twitter Pinterest Tumblr Copy Link Link Copied Phoenix Sideloader Designed for labs running thousands of samples a year. Load the autosampler, walk away, and let it run unattended. Optional 30 or 50-cup autosampler Unattended, continuous operation Uses ISI ring cups (ground, homogeneous samples) Request a Consultation For sample flexibility Play Video Facebook Twitter Pinterest Tumblr Copy Link Link Copied Phoenix Top Window Designed for universities, and labs that analyze a range of sample types. Multiple cup types in one instrument Scans 99% of the sample area for lower sampling error Integrated check standard with drift prevention Request a Consultation Phoenix 6000: Designed for Ease of Use Easy Operation Fill the cup, set it on the instrument, and scan — results in about 30 seconds. Flexible Data Handling Export results to Excel, LIMS, or Modbus, and review history anytime in BlueScan. Expert Support Our technology managers average 10+ years of hands-on NIR experience. High Performance NIR A scanning monochromator— a trusted NIR technology for reliable, precise, consistent results. Intuitive Software A simple four-tab, color-coded interface that operators learn and use with ease. Made in USA Every Phoenix 6000 is built and shipped from our headquarters in Maryland, USA. Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- NIR for Oilseed Processing | Phoenix Analyzers | Blue Sun
Near-infrared (NIR) analysis for the oilseed industry: moisture, oil, protein, fiber, and chlorophyll across whole seed, press cake, meal, and finished oil NIR Designed for Oilseed Processing & Breeding Whole seed, flakes, press cake, meal, pomace, crude oil and by-products — the Phoenix NIR analyzer measures every stream in your process on one instrument, in about 30 seconds. Request Information Explore the Analyzers One NIR instrument for every stream in the plant Most oilseed operations end up with separate methods for seed, for meal and for oil. The Phoenix Top Window takes all three on the same instrument — you change the cup, not the analyzer. Three cup types cover everything from unground whole seed to finished oil. That matters beyond the equipment list. When incoming seed, press cake and finished oil are all read on one instrument, the numbers sit on a common basis — the residual oil at the press is directly comparable to the oil you graded on the way in, instead of two methods you have to reconcile. And because the Phoenix is fully sealed to IP62, the same analyzer works in the QA lab or out at the press, so lab and at-line results don't drift apart. Three cup types, for every product you measure Large Cup Solids, ground and unground Ring Cup Ground samples and seed Transflectance Cup Liquids Explore the Oilseed Analyzer → Load up to fifty samples, walk away, get the seed back intact Breeding programs are throughput problems. The Phoenix Sideloader with Autosampler runs batches of 30–50 unattended — or continuously, as you keep adding cups — and the analysis is non-destructive, so every seed you screen is still available to plant. Identity travels with the cup, not the worklist Automating sample handling usually just relocates the clerical work: the cup is anonymous, its identity comes from its slot in the rack, and an operator maintains a worklist to match them up. One cup in the wrong position and every result after it attaches to the wrong seed line. The RFID tag system removes that failure mode — the sample ID and product code are written to the cup's own tag, and the Phoenix reads them back at the moment of the scan so you can load the rack in any order. Explore the Canola Analyzer → Measured head-to-head on soybean meal — and it led the field A prospective buyer designed and ran the test: the Phoenix against three competing NIR and FT-NIR analyzers on soybean-meal protein. All four ran the same 21 samples, each on its own native commercial calibration, against an independent validation set held out from calibration. How the evaluation was run The customer designed and ran the evaluation — not the vendor Same 21 soybean-meal samples, protein 44.4–47.6% Each analyzer on its own native commercial calibration Results compared against the reference laboratory, with no bias or slope adjustment applied The Result The Phoenix had the lowest prediction error of the four analyzers: an SEP of 0.28% protein (R² 0.86), compared with 0.57, 0.65 and 0.90% (R² 0.52, 0.27 and 0.15) for the three competing NIR and FT-NIR analyzers. Explore the Soybean Analyzer → Screening thousands of seed lines without spending the seed Pennycress is being bred from a common weed into an aviation-fuel crop — a winter cover crop whose oil suits renewable diesel and jet fuel. Reaching that point meant characterizing thousands of genetic lines for oil, moisture and protein. The Phoenix NIR analyzer is what made screening at that volume possible. The seed is worth more than the measurement Early-generation breeding material exists in quantities too small to spend on a wet-chemistry test — consume the sample to measure it and the line is gone. Spectral data collected across thousands of seed samples was used to build calibration models predicting oil content, moisture and protein composition, and because the measurement is non-destructive, the same seed continued straight into the next generation. That changed what the program could evaluate. Analysis time and cost dropped enough to support genuinely high-throughput selection — which is the constraint that decides how quickly a new crop reaches commercial scale. Read "Breeding a Better Biofuel" THIS IS NIR DESIGNED FOR OILSEED ANALYSIS See how the Phoenix fits your plant or breeding program Tell us your samples and throughput, and we'll match you to the right configuration and calibrations — with a hands-on evaluation on your own material. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- Blue Sun Scientific | NIR Analyzers for Food & Agriculture
Phoenix NIR analyzers for forage, feed, pet food, oilseed, rendering, dairy and seed breeding. Fast, reagent-free analysis. Designed and built in the USA. Phoenix NIR Analyzers for Agriculture and Food Our Phoenix NIR solutions cater to the agricultural and food industries, offering rapid and non-destructive analysis for forage, animal feed, pet food, oilseeds, plant breeding, and more. We understand the unique challenges of these sectors and are committed to supporting our customers with expert knowledge and trusted support. Talk to a Specialist or call (410) 705-2279 Replaces wet-chemistry methods One scan, many parameters Results in seconds, not hours No reagents, minimal prep Scanning Monochromator High resolution across the whole NIR range Optional Autosampler Run samples unattended NIR built for how you work Every analyzer runs on the same Phoenix platform — choose the path that matches your operation. Animal Nutrition Rapid NIR analysis for forage, feed, rendering, and pet food — lab-grade accuracy from raw ingredient to finished product. Explore Animal Nutrition → Wheat Milling Protein, moisture, and ash from incoming wheat to finished flour — whole grain and flour analysis on a single instrument. Explore Wheat Milling → Oilseed Accurate oil, protein, and moisture analysis on seed and meal — NIR built for crushers, processors, and seed breeders. Explore Oilseed → Dairy Fat, moisture, protein, and salt in cheese, butter, whey, and powders — fast results that keep standardization and yield on target. Explore Dairy → University & Research One flexible platform for research and teaching labs — measure virtually any sample type and develop your own calibrations. Explore Research → Snack Food Oil, moisture, and seasoning on chips and extruded snacks — accuracy that controls fryer performance and seasoning consistency Explore Snack Food → READY WHEN YOU ARE See how the Phoenix fits your operation Tell us your samples and throughput and we'll match you to the right configuration — with a hands-on evaluation on your own material. Talk to a Specialist Browse the Analyzers
- Pet Food NIR Analyzer | Phoenix 5000 | Blue Sun
Rapid NIR analysis of pet food — measure moisture, protein, fat, fiber, starch and ash in about 30 seconds with the Phoenix 5000. Made in the USA. Phoenix 5000 NIR Petfood Analyzer Get fast, reliable pet food analysis in seconds. The Phoenix 5000 pet food NIR analyzer reads moisture, protein, fat, fiber, starch, and ash from a single scan — reagent-free and non-destructive — so pet food makers can verify incoming quality, hold extrusion and drying on target, and meet their guaranteed analysis without the wait. Designed, built, and supported in the USA. Download Brochure Request Information Get to Know the Phoenix 5000 Petfood Types Dry Petfood Track moisture, protein, and fat from receiving through the mixer and dryer to finished kibble, keeping extrusion on spec. Wet Petfood Check moisture, protein, and fat across receiving, mixing, and finished product to keep canned and pouch recipes on spec. Treats Confirm moisture, protein, and fat at incoming inspection and on the finished treat, ensuring every batch meets specification. What the Phoenix NIR 5000 Measures Ash Indicates mineral content and flags contamination Starch Supports recipe formulation and energy calculations Fiber Assesses ingredient quality and digestibility Fat Monitors energy content and tracks fat through extruders, dryers, and coating Protein Confirms formulation targets and the guaranteed analysis on the label Moisture Controls incoming ingredient quality and prevents over- or under-drying How Petfood Makers Use NIR Analysis Pet food production holds tight specs at every stage, from receiving raw materials to finished product — and each one depends on knowing exactly what's in the batch. The Phoenix 5000 puts fast, reliable analysis right on the line: moisture, protein, fat, fiber, starch and ash in about 30 seconds, with no reagents and no waiting on an outside lab. So you can catch issues as they happen, keep batches consistent, and confirm every run against its label before it ships. Ingredients Check moisture and quality of raw materials on arrival Confirm meals, fats, and premixes meet your formula's specs Production Control Track moisture and fat through the extruder and dryer in seconds Hold targets steady and tighten control limits to cut variability Finished Product Verify finished product against the guaranteed analysis on the label Reduce reliance on outside lab testing and its cost NIR vs. Wet Chemistry: Why Petfood Makers Choose NIR Wet chemistry is the accuracy benchmark — but it's slow, reagent-heavy, and costly per sample. NIR delivers results correlated to those same reference methods in seconds, so you can test far more often without the wait, the chemicals, or the lab bill. NIR Wet Chemistry Where you run it On-site, in-process Usually in a lab Cost per test Very low Higher (reagents + labor) Parameters per run Several at once One assay at a time Sample Non-destructive Sample consumed Reagents None Chemical reagents required Speed ~ 30 seconds Hours to days Wet chemistry remains the reference standard that NIR calibrations are built on — so NIR is your fast, everyday tool, with wet chemistry as the benchmark behind it. Read more: [NIR vs. Wet Chemistry for Petfood Analysis] Phoenix 5000: Designed for Ease of Use Easy Operation Fill the cup, set it on the instrument, and scan — results in about 30 seconds. Flexible Data Handling Export results to Excel, LIMS, or Modbus, and review history anytime in BlueScan. Expert Support Our technology managers average 10+ years of hands-on NIR experience. High Performance NIR A scanning monochromator— a trusted NIR technology for reliable, precise, consistent results. Intuitive Software A simple four-tab, color-coded interface that operators learn and use with ease. Made in USA Every Phoenix 5000 is built and shipped from our headquarters in Maryland, USA. Phoenix 5000 Specifications TECHNOLOGY & PERFORMANCE NIR Technology Scanning Monochromator Detector High-performance InGaAs Wavelength Range 1100-2500 nm Spectral Resolution 0.5, 1.0, 2.0 nm (selectable) Measurement Mode Reflectance or transflectance Analysis Time 10 - 60 seconds (~30 seconds typical) Wavelength Accuracy <0.05 nm matched to an internal reference standard Drift Control Internal Drift Prevention with embedded standards SAMPLE HANDLING Sample Cups Large, small, custom Sample Prep Little to none DATA & SOFTWARE Software BlueScan Data Export Excel, LIMS, Modbus Operating System Windows 10/11 Need the complete datasheet? The brochure has full dimensions, power and environmental specs, as well as the Phoenix 5000 vs. 6000 comparison.[Download the Phoenix brochure (PDF)] Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- Oilseed Analyzer | NIR Analyzer
Analyze oilseeds quickly and easily for a variety of critical parameters - important to oilseed crushers and seed breeders. Phoenix 5000 NIR Oilseed Analyzer Rapid NIR Analysis for moisture, protein, fat, fiber, ash, oleic acid, linoleic acid and more. Analyze oilseeds such as canola/rapeseed, soybean, olive oil, and more. Optimize the extraction process by analyzing pressed cake and meals Determine oil quality by analyzing for free fatty acids and peroxide value. Download Brochure Request Information Phoenix 5000 NIR for Oilseed Analysis The Phoenix Top Window by Blue Sun Scientific is an ideal solution for oilseed processors and crushers that are seeking to optimize yields and produce a consistent, high-quality oil. The Phoenix Top Window’s sampling system allows it to analyze whole seeds, flakes, press cake, oilseed meals, oil, and by-products. Multiple parameters can be measured simultaneously including moisture, protein, fat, fiber, ash, oleic acid, and linoleic acid as well as chlorophyll in rapeseed/canola. The Phoenix 5000 can help oilseed crushers optimize production in multiple ways including: Raw Material Grading Monitor quality of incoming oilseeds Process Control Analyze residual oil in pressed cake Rapid decision making Oil Quality Determine oil quality by analyzing free fatty acids, acid value, iodine value, and peroxide value By-products Measure moisture, protein, oil, fiber and ash in pressed cakes and meals Maximize profits on by-products Get to Know the Phoenix 5000 Phoenix 5000: Designed for Ease of Use Easy Operation To analyze a sample, fill the sample cup, place it on the instrument, and press the on-screen scan button. Analysis will begin immediately and results will be displayed in approximately 30 seconds. Expert Support Blue Sun Scientific technology managers have on average 10+ years of NIR experience in a variety of NIR technologies and applications Intuitive Software The Phoenix software's four tab design utilizes color coded buttons and tabs to allow operators to learn and use the instrument easily. Flexible Data Handling Operators can easily export results to Excel, LIMS, or modbus. Historical results can quickly be viewed in the BlueScan sofrware. High Performance NIR The Phoenix 5000 delivers exceptional reliability, precision and accuracy by utilizing a scanning monochromator, the most trusted NIR technology for producing consistent results. Made in USA Each Phoenix 5000 is built and shipped from our company's headquarters in Maryland, USA. Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Email* Phone Company Application* Submit
- Phoenix 5000 Top Window NIR Analyzer | Benchtop NIR | Blue Sun
Benchtop scanning-monochromator NIR analyzer (1100–2500 nm). Scans the whole sample cup in ~30 seconds for forage, feed, pet food and more. Made in USA. Phoenix 5000 Top Window NIR Analyzer The Phoenix NIR Analyzer is an ideal solution for manufacturers and laboratories that require rapid, accurate and reliable NIR analysis. The Phoenix employs a scanning monochromator, which is the NIR technology highly trusted by both agriculture and food companies as well as laboratories around the world. Download Brochure Request Information 1100-2500nm Standard NIR Wavelength Range The comprehensive wavelength range in NIR analysis, specifically from 1100 to 2500 nm, provides a rich dataset that is ideal for agricultural and food analysis due to its ability to capture critical absorption bands associated with essential components like moisture, protein, fat, fiber, and starch. This wavelength range allows for a thorough and representative scan, essential in agricultural and food products where uniformity and composition can vary significantly. Innovative Sample Car The Phoenix 5000's innovative sample car is compatible with a variety of sample cups to allow diverse sample types to be analyzed on the same instrument seamlessly. The sample car’s design accommodates a large open cup , perfect for bulkier or coarser samples like whole grains or chopped forage. The Phoenix also supports a smaller ring cup , suited for finer or homogenous powders like flour. Additionally, the sample car’s compatibility with a transflectance cup provides the option to analyze liquids or semi-solid samples, such as oils or slurries, which have unique handling requirements compared to dry materials. Phoenix 5000 Scan Area Other NIR Scan Area Total Sample Scan A key differentiator of the Phoenix 5000 top window is its innovative capability to move the sample cup both laterally and rotationally, enabling it to scan nearly the entire sample area. This unique design ensures a highly representative analysis by covering a significantly larger portion of the sample compared to conventional NIR analyzers, which typically scan only around 33% of the cup. By traversing the full surface of the sample, this instrument effectively accounts for any natural variability or inhomogeneity, delivering more precise and dependable data. This capability is especially beneficial for agricultural and food products, where variations in particle size, density, and composition can otherwise impact accuracy if only a small portion of the sample is examined. Designed for Ease of Use Standard Wavelength Range 1100-2500 nm wavelength range is optimal for most food and agricultural applications. Top Window Design Fully sealed design is suitable for both laboratory and at-line NIR analysis in production environments. Innovative Sample Handling The Phoenix 5000 Top Window's innovative sample car allows for a variety of sample cups to analyze both ground and unground as well as liquid samples. Easy Operation To analyze a sample, fill the sample cup, place it on the instrument, and press the on-screen scan button. Analysis will begin immediately and results will be displayed in approximately 30 seconds. Expert Support Blue Sun Scientific technology managers have on average 10+ years of NIR experience in a variety of NIR technologies and applications Intuitive Software The Phoenix software's four tab design utilizes color coded buttons and tabs to allow operators to learn and use the instrument easily. Flexible Data Handling Operators can easily export results to Excel, LIMS, or modbus. Historical results can quickly be viewed in the BlueScan software. High Performance NIR The Phoenix 5000 delivers exceptional reliability, precision and accuracy by utilizing a scanning monochromator, the most trusted NIR technology for producing consistent results. Made in USA Each Phoenix 5000 is built and shipped from our company's headquarters in Maryland, USA. Frequently asked questions What types of products can Blue Sun Scientific analyzers test? Blue Sun Scientific offers NIR analyzers for dairy, olive products, spices, animal feed, breakfast cereal, snack food, rendering products, soybeans, forages, feeds, and oilseeds. The company also provides analytical solutions for food, agricultural, and environmental analysis. What maintenance does the Phoenix require? Very little - Routine care is mostly keeping sample cups and the scan window clean, and running a quick instrument check:Performance checks: run the built-in diagnostic test weekly. It checks wavelength accuracy, repeatability and noise in under 10 minutes.Lamp: most users replace the lamp once or twice a year. The tungsten halogen lamp typically lasts 5,000–10,000 hours and can be changed by the user in under 5 minutes with no special tools.Cleaning: keep sample cups and the window clean and free of residue between samples.Environment: stable power, a level bench free of vibration, and temperatures of 10–40 °C with humidity below 85% keep results consistent.For more detail, see Extending the Life of Your NIR Instrument. Can I use my existing calibrations? Yes. The Phoenix can transfer existing customer-owned calibration databases from many other NIR manufacturers, and its wavelength data can be configured to match your current instruments. What's the difference between the Top Window and Side Loader? The Top Window takes large, small and custom cups, so it suits labs and plants testing many sample types, including unground and liquid samples. The Side Loader uses ring cups and adds an optional 30- or 50-cup autosampler for high-volume, unattended testing. What's the difference between the Phoenix 5000 and 6000? The 5000 covers 1100–2500 nm with one InGaAs detector, which suits most food and agricultural work. The 6000 extends the range to 600–2500 nm with a second silicon detector, for research and applications that need NIR data found in the 600-1100nm region of the spectrum. Phoenix 5000 Specifications TECHNOLOGY & PERFORMANCE NIR Technology Scanning Monochromator Detector High-performance InGaAs Wavelength Range 1100-2500 nm Spectral Resolution 0.5, 1.0, 2.0 nm (selectable) Measurement Mode Reflectance or transflectance Analysis Time 10 - 60 seconds (~30 seconds typical) Wavelength Accuracy <0.05 nm matched to an internal reference standard Drift Control Internal Drift Prevention with embedded standards SAMPLE HANDLING Sample Cups Large, small, custom Sample Prep Little to none DATA & SOFTWARE Software BlueScan Data Export Excel, LIMS, Modbus Operating System Windows 10/11 Need the complete datasheet? The brochure has full dimensions, power and environmental specs, as well as the Phoenix 5000 vs. 6000 comparison.[Download the Phoenix brochure (PDF)] Application Support The Phoenix 5000 Top Window is well suited for a variety of applications. Select an application below for more information. Canola Feed Olive Oil Rendering Spices Chocolate Flour Petfood Snack food Tobacco Dairy Forage Potato Soybean University Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- Phoenix 6000 Side Loader NIR Analyzer | 600–2500 nm | Blue Sun
Extended-range NIR analyzer (600–2500 nm) with dual detectors and optional 30- or 50-cup autosampler for high-throughput, unattended testing. Made in USA. Phoenix 6000 Side Loader NIR Analyzer The Phoenix NIR Analyzer is an ideal solution for manufacturers and laboratories that require rapid, accurate and reliable NIR analysis. The Phoenix Sideloader is compatible with an optional autosampler for laboratories that require the highest throughput and most reliable NIR analysis. Download Brochure Request Information 600-2500nm Extended NIR Wavelength Range The expanded wavelength range of 600 to 2500 nm in NIR analysis captures a richer dataset, making it ideal for researchers and specialized applications that benefit from the extended range, such as chlorophyll analysis in canola. This extended range enables a thorough, representative scan that supports diverse and detailed analyses, particularly beneficial in agricultural and food products where composition and uniformity can vary significantly. The expanded capability is perfect for advanced applications, helping researchers obtain precise and meaningful data across a wide range of samples . Autosampler Option The Phoenix 5000 Sideloader can supplemented with an optional autosampler for high-throughput-automated analysis. The autosampler is compatible with industry standard ring cups. making it an ideal solution for forage laboratories, seed breeders, and commercial laboratories. There are two autosampler models for either 30 sample or 50 sample capacities. The autosampler solution is fully automated, allowing operators to program entire runs and walk away while the Phoenix Sideloader with Autosampler analyzes the entire run unattended. Designed for Ease of Use Extended Wavelength Range 600-2500 nm wavelength range is optimal for researchers and select applications. Side Loader Design Compatible with standard ring cups, the Phoenix Sideloader is idea for ground, homogeneous samples and seeds. Innovative Sample Handling The Phoenix 5000 Top Window's innovative sample car allows for a variety of sample cups to analyze both ground and unground as well as liquid samples. Easy Operation To analyze a sample, fill the sample cup, place it on the instrument, and press the on-screen scan button. Analysis will begin immediately and results will be displayed in approximately 30 seconds. Expert Support Blue Sun Scientific technology managers have on average 10+ years of NIR experience in a variety of NIR technologies and applications Intuitive Software The Phoenix software's four tab design utilizes color coded buttons and tabs to allow operators to learn and use the instrument easily. Flexible Data Handling Operators can easily export results to Excel, LIMS, or modbus. Historical results can quickly be viewed in the BlueScan sofrware. High Performance NIR The Phoenix 6000 delivers exceptional reliability, precision and accuracy by utilizing a scanning monochromator, the most trusted NIR technology for producing consistent results. Made in USA Each Phoenix 6000 is built and shipped from our company's headquarters in Maryland, USA. Application Support The Phoenix 5000 Top Window is well suited for a variety of applications. Select an application below for more information. Canola Feed Olive Oil Rendering Spices Chocolate Flour Petfood Snack food Tobacco Dairy Forage Potato Soybean University Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- Phoenix 6000 Top Window NIR Analyzer | 600–2500 nm | Blue Sun
High-throughput NIR analyzer (1100–2500 nm) with optional 30- or 50-cup autosampler for unattended forage, feed and pet food testing. Made in USA. Phoenix 6000 Top Window NIR Analyzer The Phoenix NIR Analyzer is an ideal solution for researchers and laboratories that require rapid, accurate and reliable NIR analysis. The Phoenix 6000 employs a scanning monochromator, with an extended wavelength range from 600-2500 nm, for applications that require the entire NIR spectrum. Download Brochure Request Information 600-2500nm Extended NIR Wavelength Range The expanded wavelength range of 600 to 2500 nm in NIR analysis captures a richer dataset, making it ideal for researchers and specialized applications that benefit from the extended range, such as chlorophyll analysis in canola. This extended range enables a thorough, representative scan that supports diverse and detailed analyses, particularly beneficial in agricultural and food products where composition and uniformity can vary significantly. The expanded capability is perfect for advanced applications, helping researchers obtain precise and meaningful data across a wide range of samples . Innovative Sample Car The Phoenix 6000's innovative sample car is compatible with a variety of sample cups to allow diverse sample types to be analyzed on the same instrument seamlessly. The sample car’s design accommodates a large open cup , perfect for bulkier or coarser samples like whole grains or chopped forage. The Phoenix also supports a smaller ring cup , suited for finer or homogenous powders like flour. Additionally, the sample car’s compatibility with a transflectance cup provides the option to analyze liquids or semi-solid samples, such as oils or slurries, which have unique handling requirements compared to dry materials. Phoenix 6000 Scan Area Other NIR Scan Area Total Sample Scan A key differentiator of the Phoenix 6000 top window is its innovative capability to move the sample cup both laterally and rotationally, enabling it to scan nearly the entire sample area. This unique design ensures a highly representative analysis by covering a significantly larger portion of the sample compared to conventional NIR analyzers, which typically scan only a limited section. By traversing the full surface of the sample, this instrument effectively accounts for any natural variability or inhomogeneity, delivering more precise and dependable data. This capability is especially beneficial for agricultural and food products, where variations in particle size, density, and composition can otherwise impact accuracy if only a small portion of the sample is examined. Designed for Ease of Use Extended Wavelength Range 600-2500 nm wavelength range is optimal for researchers and select applications. Top Window Design Fully sealed design is suitable for both laboratory and at-line NIR analysis in production environments. Innovative Sample Handling The Phoenix 5000 Top Window's innovative sample car allows for a variety of sample cups to analyze both ground and unground as well as liquid samples. Easy Operation To analyze a sample, fill the sample cup, place it on the instrument, and press the on-screen scan button. Analysis will begin immediately and results will be displayed in approximately 30 seconds. Expert Support Blue Sun Scientific technology managers have on average 10+ years of NIR experience in a variety of NIR technologies and applications Intuitive Software The Phoenix software's four tab design utilizes color coded buttons and tabs to allow operators to learn and use the instrument easily. Flexible Data Handling Operators can easily export results to Excel, LIMS, or modbus. Historical results can quickly be viewed in the BlueScan sofrware. High Performance NIR The Phoenix 5000 delivers exceptional reliability, precision and accuracy by utilizing a scanning monochromator, the most trusted NIR technology for producing consistent results. Made in USA Each Phoenix 5000 is built and shipped from our company's headquarters in Maryland, USA. Application Support The Phoenix 5000 Top Window is well suited for a variety of applications. Select an application below for more information. Canola Feed Olive Oil Rendering Spices Chocolate Flour Petfood Snack food Tobacco Dairy Forage Potato Soybean University Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- Phoenix 5000 Side Loader NIR Analyzer | Autosampler | Blue Sun
High-throughput NIR analyzer (1100–2500 nm) with optional 30- or 50-cup autosampler for unattended forage, feed and pet food testing. Made in USA. Phoenix 5000 Side Loader NIR Analyzer The Phoenix NIR Analyzer is an ideal solution for manufacturers and laboratories that require rapid, accurate and reliable NIR analysis. The Phoenix Sideloader is compatible with an optional autosampler for laboratories that require the highest throughput and most reliable NIR analysis. Download Brochure Request Information 1100-2500nm Standard NIR Wavelength Range The comprehensive wavelength range in NIR analysis, specifically from 1100 to 2500 nm, provides a rich dataset that is ideal for agricultural and food analysis due to its ability to capture critical absorption bands associated with essential components like moisture, protein, fat, fiber, and starch. This wavelength range allows for a thorough and representative scan, essential in agricultural and food products where uniformity and composition can vary significantly. Autosampler Option The Phoenix 5000 Sideloader can supplemented with an optional autosampler for high-throughput-automated analysis. The autosampler is compatible with industry standard ring cups. making it an ideal solution for forage laboratories, seed breeders, and commercial laboratories. There are two autosampler models for either 30 sample or 50 sample capacities. The autosampler solution is fully automated, allowing operators to program entire runs and walk away while the Phoenix Sideloader with Autosampler analyzes the entire run unattended. Designed for Ease of Use Standard Wavelength Range 1100-2500 nm wavelength range is optimal for most food and agricultural applications. Side Loader Design Compatible with standard ring cups, the Phoenix Sideloader is idea for ground, homogeneous samples and seeds. Innovative Sample Handling The Phoenix 5000 Top Window's innovative sample car allows for a variety of sample cups to analyze both ground and unground as well as liquid samples. Easy Operation To analyze a sample, fill the sample cup, place it on the instrument, and press the on-screen scan button. Analysis will begin immediately and results will be displayed in approximately 30 seconds. Expert Support Blue Sun Scientific technology managers have on average 10+ years of NIR experience in a variety of NIR technologies and applications Intuitive Software The Phoenix software's four tab design utilizes color coded buttons and tabs to allow operators to learn and use the instrument easily. Flexible Data Handling Operators can easily export results to Excel, LIMS, or modbus. Historical results can quickly be viewed in the BlueScan sofrware. High Performance NIR The Phoenix 5000 delivers exceptional reliability, precision and accuracy by utilizing a scanning monochromator, the most trusted NIR technology for producing consistent results. Made in USA Each Phoenix 5000 is built and shipped from our company's headquarters in Maryland, USA. Application Support The Phoenix 5000 Top Window is well suited for a variety of applications. Select an application below for more information. Canola Feed Olive Oil Rendering Spices Chocolate Flour Petfood Snack food Tobacco Dairy Forage Potato Soybean University Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit
- Support | Blue Sun Scientific
Flexible severice and support options for all of our insturments as well as many legacy instruments from other NIR manufacturers. Service and Support Welcome to the Support Desk We are here and ready to service your NIR instruments. Whether your instrument needs repair, application support, calibration development or a service contract, you can best reach us using this contact form. A service representative will promptly review your request and contact you with all of our available solutions. For urgent service requests, please call our service department at: (410) 705-2279 ext 1
- Chocolate Analyzer | NIR Analyzer
Optimize in-process moisture, fat, sugar & FFA levels of chocolate and confirm the quality of ingredients and finished product. Phoenix 5000 NIR Chocolate Analyzer Rapid NIR Analysis for moisture, fat, sugar and ffa. Control moisture and quality for incoming cocoa beans Analyze nibs for moisture and fat Determine fat and moisture for cocoa liquor for pricing Determine fat for cocoa powder for pricing Confirm moisture, fat and sugar for consistent chocolate quality Download Brochure Request Information Phoenix 5000 NIR for Chocolate production The Phoenix 5000 NIR analyzer brings precision and efficiency to chocolate production, enabling fast, at-line and laboratory analysis of raw materials, in-process, and finished chocolate products—all on the same instrument. The Phoenix 5000 provides fast, simultaneous measurements of key quality attributes, such as fat, moisture, sugar content & ffa, giving chocolate producers essential data to maintain product consistency, optimize recipes, and ensure high quality across batches. With the Phoenix 5000, chocolate manufacturers can improve production processes in areas like: Ingredients Monitor quality of incoming cacao beans Production Control 30 second analysis of in-process product Rapid decision making Pricing Determine fat & moisture for cocoa liquor Determine fat for cocoa powder Final Product Specification Confirm quality of finished product Label deck Reduce laboratory costs Get to Know the Phoenix 5000 Phoenix 5000: Designed for Ease of Use Easy Operation To analyze a sample, fill the sample cup, place it on the instrument, and press the on-screen scan button. Analysis will begin immediately and results will be displayed in approximately 30 seconds. Expert Support Blue Sun Scientific technology managers have on average 10+ years of NIR experience in a variety of NIR technologies and applications Intuitive Software The Phoenix software's four tab design utilizes color coded buttons and tabs to allow operators to learn and use the instrument easily. Flexible Data Handling Operators can easily export results to Excel, LIMS, or modbus. Historical results can quickly be viewed in the BlueScan sofrware. High Performance NIR The Phoenix 5000 delivers exceptional reliability, precision and accuracy by utilizing a scanning monochromator, the most trusted NIR technology for producing consistent results. Made in USA Each Phoenix 5000 is built and shipped from our company's headquarters in Maryland, USA. Want to Know More? Please take a moment to tell us more about your application and a Blue Sun Scientific NIR specialist will promptly be in contact to discuss your application and answer all of your questions. First name* Last name* Company name* Email* Phone* Describe your Application* Submit





